Pro 1000 Case Sensor Assembly
The correct order for assembly of the primer feed on the Pro-1000 is as follows;
First drop in the primer pin, with the long end facing up. Then slide the primer spring over. the long end of the primer pin. Then press the primer trough into the recess in the shellplate carrier.
The case sensor is assembled as follows; First place the tension finger on the shellplate carrier casting, with the hooked end around the small pin cast as part of the carrier casting. Then slide the small end of the case sensor bushing into the hole in the case sensor, and insert the case sensor screw through the small end of the case sensor bushing. Place this assembly on top of the tension finger, so the screw threads into the hole in the shellplate carrier casting. Do not
over tighten the case sensor screw, the case sensor must be free to pivot on the case sensor bushing.